Verify the connection method and prerequisites
Ask which portal, API, local component, or file-based process is used. Establish whether vendor approval, a partner relationship, specific software versions, account settings, or other prerequisites are required. Confirm the scope for your region and lab account.
Use the vendors' own documentation for platform context. iTero describes LMS integration artifacts and export settings; 3Shape and Medit document their own case exchange and file workflows. Those documents explain the source platforms, not the availability of a particular third-party product's connector.
Inspect what is actually transferred
List required fields and assets: source reference, clinic, requested work, due dates where available, scan files, prescription, and supporting attachments. Mark which values transfer automatically and which staff must supply or review. Test formats with the software used downstream.
Check whether a preview image represents the underlying file or merely a thumbnail. Ask when a case is considered complete enough to review and what happens if additional artifacts arrive later. A successful initial event does not necessarily mean the whole package is ready.
Test new, revised, and duplicate work
Start with a new case, then change its instructions or files through the supported source workflow. Observe whether the existing lab record is updated, a review is requested, or another case is created. Keep the source reference visible through the process.
Repeat an event or retry a transfer after an interruption. The integration should have an explained policy for duplicates and partial success. Ask how staff can distinguish a new order from an amended version without comparing downloads manually.
Evaluate timing and error visibility
Ask whether updates are event-driven, periodically checked, or initiated by a person. Use the agreed terminology rather than describing every process as real time. Confirm the behavior when credentials expire, permissions change, or the source becomes unavailable.
Request a visible exception record with an owner and recovery path. Staff should know what needs attention without reading server logs. Clarify which vendor supports the first response and how cross-vendor issues are escalated.
Follow acceptance into the lab workflow
Receiving scanner data is one integration boundary; creating a structured production case is another. Demonstrate how the source's product information maps to your catalog and how required fields are reviewed. Confirm what happens when a mapping is absent or ambiguous.
If you retain another LMS, follow the accepted case into that system too. Establish which system owns the case status, due date, and updates. Two systems displaying similar information do not prove that changes remain synchronized correctly.
Document an acceptance test
Use a matrix of source, account prerequisites, expected data, test case, result, limitation, and responsible owner. Include a representative file package for each source and at least one failure or revision. Agree the acceptance conditions before the integration is treated as production-ready.
For LabOptIQ, ask for current supported-source details and a scoped demonstration using your portal list. Keep proposed integrations and confirmed capabilities separate. A believable integration evaluation ends with tested behavior and known limitations, not only a collection of connected logos.
View A Workflow Example

Explore this workflow with your team.
Bring your cases, scanner sources, and existing tools to a LabOptIQ demo. Confirm the handoffs, available features, and integration scope that matter to your lab.
Book A Workflow DemoSources & Further Reading
- iTero: LMS integration specification and export settings
- 3Shape: Case updates between clinics and labs
- Medit: File Viewer and supported data
Vendor documentation explains its own platform, not a confirmed LabOptIQ integration or partnership.